The charger features charging, charging with preliminary discharging, the measuring of battery pack capacity and testing of one to eight RF13.1 (NiCd) and the RF13.13 (LiIon) battery packs. Any of the four functions may be independently used in each of the eight locations. These functions are selected by function switch. After the battery pack is connected to the particular location, the selected function gets running.

PN (RN): 7024.100.01
Supply voltage (90 to 264) V, 50 Hz
Current consumption max. 10 A
No-load current consumption max. 0.5 A
Standard charging time 14 hours to 15 hours for RF13.1
Quick charging time 60 minutes for RF13.1
Charging time max. 7 hours for RF13.13
Operating temperature range of RF13.1 battery packs for quick charging +10 ºC to +43 ºC
Operating temperature range of RF13.13 battery pack for charging 0 ºC to +50 ºC
Battery pack testing current 2 A
Protection provided by enclosure IP 30
Dimensions W 430 mm x H 250 mm x D 255 mm
Weight 10 kg
NU13 operating instructions 7024.010.02
Switch display: Catalog / List
Sort by

NU13 - Universal charger set

PN (RN): 7024.000.02

Set consists of NU13 universal charger and accessories. The charger features charging, charging with preliminary discharging, the measuring of battery...

Switch display: Catalog / List
Sort by

RF13.1 - Rechargeable battery pack set

PN (RN): 7000.000.02

Set consists of RF13.1 battery pack and documentation. For basic operation no other components are required. RF13.1 is...

RF13.13 - Rechargeable battery pack

PN (RN): 7000.100.22

Power supply for RF13 portable transceiver. It contains a set of LiIon batteries in serial-parallel connection with protective and diagnostic...